It might be easier to determine the R from a lookup table rather than a reverse calculation, though that view might be because I’m struggling with the maths. I’m with AllyCat; putting the resistor under test at the bottom and using FVR for Vref+ you should be able to get down to +/- 0.5 ohm. Another method, depending on which PICAXE you are galactrum price using, is to set the bottom of the ADC range to a different value than 0v. If you make R2 significantly smaller, say 51ohm, then the range is 0.7v to 5v. The linearization table or voltage curve is not used when you select K-Type as the input. Failure to heed this warning may result in death or serious injury to yourself and/or others.

Put that in parallel with a 510R reference resistor and it will change that. If put across the resistor to test it will affect the circuit non-linearly. Firstly, by putting any device (e.g. current limiter) in series with the voltage Reference, you appear to have largely eliminated it’s function of being an accurate Reference voltage ! Also, the mantra for achieving high reliability is generally to KISS .
Syvecs Forums
Not really his fault as this was a totally new type of job for him. I think the source of the issue might be that I’m using solid core Cat 6 cable, which is a bit stiff, and seems to exert some torque on the connector. You can have a modern full HD software compatible Atari laptop! I’ve been looking for a raspberry pi powered laptop for a long time and finally this is a reasonably priced unit. There are already tools online available to help teachers to take the first steps into designing on a 3D printer, such as TinkerCAD .
I am pretty sure (although still browsing the finer details of numerous datasheets, now inclusive of Hippy’s suggestion of HX711) I am going to go with an external ADC. Thus far the MCP3421 in singled-ended mode appears to be one of the best fits regards to the math and truly achieving the 0.1 ohm resolution I am looking for. This will then leave the accuracy coming down to my electronic design. Reference to the image I posted in POST #1, R1 will be raised to 1K or in practice at worst I may end up having to suffer with the current expense of using 510R and R2 shall be the resistor under test. Of course anything you attach to the circuit must reach the same standards.
From your post, it seems you have a flat linearization for the K-Type sensors, correct? If not, please make sure to set the EGT sensor linearizations to “0” throughout. Vintage Test Gear and Workshop Equipment For discussions about vintage test gear and workshop equipment such as coil winders. There is a huge opportunity for 3D printing to offer https://cryptolisting.org/ teachers a new way to engage any and every student, no matter what their own challenges or their ages are. That’s why we’ve partnered with Kitronik to bring 3D printers to 5,000 classrooms in the UK. I believe that 3D printers should be usable by kids of all ages so that pupils have the opportunity to learn and realise their creative potential.
@moowcowsia don’t use solid core cable with all the movement the cores will work harden and fracture and that is probably what is causing your issue. You can get stranded cat5/6 cables usually as a patch cable rather than on a drum but should be easy to find and then to crimp as normal. I’m pretty sure this means that my 8-pin molex connector isn’t in good contact. The white LEDs stay on consistently, and I don’t seem to have other issues with power, so I think the 6-pin one is fine. I’m having a hard time getting a consistent connection out of the Smart Effector.
- Put that in parallel with a 510R reference resistor and it will change that.
- The other possibility is Cliff or Elma, as other have suggested it is some times easier to buy a new set that match.
- Thevenin really isn’t very difficult and sometimes can be extremely useful (Google might find a more User-friendly description than Wikipedia).
- I am pretty sure (although still browsing the finer details of numerous datasheets, now inclusive of Hippy’s suggestion of HX711) I am going to go with an external ADC.
My problem is that my watermeter, gasmeter end government-installed electricity fusebox are in one place, and from there I got a thick XVB cable to my personal fuse box at another location. I’ll make sure i take a better photo of which screw terminals ended up being 13 and 15 when i get home tonight. It will also give me a chance to hook up my single phase solar meter in the same way and hopefully my Flukso graph will populate with another line. Had meters installed this morning so I will take a few photos and hook up the pulse outputs to the Fluxso when I get home tonight. I went with the equivalent for my single phase meter. As with most issues that take a while to fix, it was a combination problem.
RS Components
The other part was that the sensitivity on the smart effector was too low. It would also be worth posting a full circuit diagram seeing as we seem to have moved on from where we started. I can’t get your readings from Post #30 to correlate with the resistances you are reading … I may be able to help there, but a prerequisite is proving your readings are what one would expect. If they aren’t then any attempted implementation to reverse those reading is simply wasted effort.
It has a maximum current of 40 Amps, 100 pulses per kWh,and is Din rail mounted. I can’t remember if you need to change the socket, as well. As a result, your viewing experience will be diminished, and you have been placed in read-only mode. Designed to provide the ultimate in accuracy, ensuring fasteners are tightened to correct specifications. Because of this I have now started working on writing a STD PIC program to be a dedicated math co-processor for this one purpose that also communicates on the I2C bus. I am getting there, but doing it this way is adding cost to the project.

Bits 31 & 30 are essentially STATUS bits and bit5 to bit0 are sub LSB’s that are ultimately insignificant noise. Not that I have finished looking around just yet, but the ADS1114 could be sufficiently suitable and offers which equates to steps, 187.5uV/step if using the 6.144v FSR or 125uV/step with a 4.096v FSR. For absolute surety, a couple ‘crowbars’ implemented in parallel will see the earth open up and swallow me whole before component failure poses any problem.
Industrial Circular Connectors
I seem to get about half of my bed to probe before one of the connectors wiggles loose, causing the effector to crash into the bed until the belt skips. Usually this happens a few times, and then the 6-blink pattern shows up once on the LED. At this stage I feel totally lost trying to programmatically extract the conversion result and then turn it into the desired figures to display on the LCD.
It may not display this or other websites correctly. RS components has all manner of pre crimped cables of various lengths. Only users with topic management privileges can see it.
The underlined component being the 24-bit conversion result I need to work with. Here’s some code to try for the cheap version you could use it at 3v and a precision resistor not really required just enter the value… Here’s some code to try for the cheap version you could use it at 3v and a precision resistor not really required just enter the value. For the beneficial purpose of this supreme forum, once I have achieved the goal, I will post the circuit along with the PICAXE code allowing it to be repeatable by any interested parties. The ADC is undoubtedly a high impedance input, as such for example a 1K resistor could be placed between the ADC input and sense point with a negligible effect to the signal.
Products
The beauty of all these features is also that it makes 3D printing accessible to anyone. For example, students with dyslexia or other learning difficulties are able to engage with lessons fully and create the object they imagine. When a person struggles with traditional learning skills like reading and writing, the key to success is often found in alternative methods to help with comprehension and inspire creativity. Over the last few years, 3D printers have become significantly more affordable for schools, not least because they offer an all-in-one package for increasingly squeezed academic budgets. This increased safety means that lessons of creative design using 3D printers could be offered as early as Key Stage 1.
Ensure that the “5 volts” can NEVER significantly exceed that voltage, for example by adding a “crowbar” circuit, in its simplest form a shunt regulator such as a zener diode. Many years ago I was told that the construction of zener diodes is such that they “always fail safe” (in the context of protecting against over-voltage) to a short circuit. I don’t know if that’s still true – anything containing bond wires can “fuse” to an open circuit . Typically then repeated with a second, Reference, resistor so the stability of the capacitor is irrelevant, it’s just the ratio of two resistances / counts. Unless something is done to adjust how the ADC is converting, the readings from READADC10 won’t be sufficiently different to be able to determine the R1 better than to +/- 1 ohm resolution.
This is true, however in this case is resolved by taking feedback from the output side of the current limiter in turn creating an offset to compensate any error. I don’t know exactly what you are doing but it sounds on par with measuring the resistance of a detonator coil inside a brick of C-4, something medical related, something with massive adverse consequences when it goes wrong. The responses are greatly appreciated and I am eternally grateful for the loan of your brain’s. I am still of the view that charging up a capacitor and timing how long that takes may be a better way to increase resolution and accuracy.
This allows children to simply click and drag to build their designs, then go on to quickly print them to see if they actually work. These tools mean a student to create 3D printer-ready objects for themselves, beginning to bridge the gap between a child’s imagination and what they’re able to create. I’m using the pulse sensor for the watermeter at a distance of more then 10 meters on a phone cable. So my problem is that I don’t have access to seperate phase cables in the location where the other meters are. Unless I cut open the isolation of the XVB to place the clamps. Totally programmable pulse frequency and length and 100% compatible with the Flukso.
If the RS one isn’t a perfect match but fits, you can always change the set of them. I have the single supply psu, will check size and see what I have later today. LandyZone is the biggest Land Rover forum on the net. We have plenty of very knowledgable members so if you have any questions about your Land Rover or just want to connect with other Landy owners, you’re in the right place.
I was thinking about something similar but wasn’t sure how it could be implemented. The first way you ensure that a circuit is accurate and reliable is to ensure that all components are operating well within their ratings. If a device is “only capable of supplying 10 mA” then it should be operated at 5 mA, or even 2 mA.
There are a few thing you can do to get better results, before you get into multi-word maths. I have researched pretty hard trying to find the clever answer to my current query. I have semi found the answer, but can’t find how I can implement my values. The other possibility is Cliff or Elma, as other have suggested it is some times easier to buy a new set that match. Read more posts like this from Chris and other guest bloggers on the TCT Blog and visit CEL Technologies at TCT Show + Personalize at the NEC Birmingham, September 30th-October 1st . “There is a huge opportunity for 3D printing to offer teachers a new way to engage any and every student, no matter what their own challenges or their ages are.”
Along with a protection zener ‘crowbar’ eliminates any of those concerns. Any adverse effect any implemented protection may have can always be software or otherwise compensated. With the “unknown” resistor on the earthy side, the measurement becomes much easier; You can use the the FVR2048 reference for the ADC and remove any need to raise the Lower Reference voltage.
Premade Cable Ends
I am very confident this setup is mathematically more than capable of achieving 0.1 ohm resolution and coupled with my appropriate reference circuit is demonstrating stable accuracy. Bottom line is that in this case error/failure stands to potentially put me to substantial expense and this is why I personally oversee and orchestrate designs and operations myself thus placing the onus solely on me. So I am confident and have the desire and mindset to just get things right upfront. Achieving 0.1 ohm resolution when measuring a one ohm resistor is relatively easy. But getting 0.1 ohm resolution of a 300 ohm resistor will be difficult, even with a 12 bit ADC.